BPJRL - 0582 LEMON, AEROSOL SPRAY PAINT

  • MSDS: BPJRL
  • Manufacturer: ZYNOLYTE PRODUCTS CO
  • Product Name: 0582 LEMON, AEROSOL SPRAY PAINT
  • National Stock Number: 8010-00N027631
Product Identification

Product ID:0582 LEMON, AEROSOL SPRAY PAINT
MSDS Date:03/23/1988
FSC:8010
NIIN:00N027631
MSDS Number: BPJRL

Responsible Party
ZYNOLYTE PRODUCTS CO
2320 E DOMINGUEZ ST
CARSON, CA 90749
US

Emergency Phone: 310-513-0700

Info Phone: 310-513-0700

Cage: 25461

Contractor
ZYNOLYTE PRODUCTS CO
6244 CARSON, CA 90749 US

Telephone: 310-513-0700

Cage: 25461

Ingredients

NON HAZARDOUS POLYMER


ORGANIC PIGMENT (NON-HAZARDOUS)


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


COBALT OCTOATE; (COBALT OCTOATE 6%) PEL/TLV AS CO

OSHA PEL 0.05 MG/M3 DUST/FUME

ACGIH TLV: 0.05 MG/M3 DUST/FUME


PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT


HYDROTREATED HEAVY NAPHTHA

CAS: 64742-48-9


PROPANE, 2-METHYL-; (ISOBUTANE)

CAS: 75-28-5

RTECS: TZ4300000


<0F,<-18C (PROPELLANT).

RTECS: 9999999ZZ


OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV

RTECS: 9999999ZZ


TOLUENE CAS#108-88-3 APPEARS ON THE NAVY

RTECS: 9999999ZZ


APPROP HLTH PROFESSIONALS CONCERN LATEST HAZ LIST

RTECS: 9999999ZZ


36.7 @ 20C.

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


25 @ 20C.

CAS: 1330-20-7

RTECS: ZE2100000

OSHA PEL 100 PPM;150 PPM STEL

ACGIH TLV: 100 PPM;150 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


10.0 @ 20C.

CAS: 64742-94-5

RTECS: WF3100000


2 @ 20C.

CAS: 64742-88-7


26 @ 20C.

CAS: 64742-89-8

OSHA PEL 300 PPM, 400 STEL

ACGIH TLV: 300 PPM


400 @ 20C.

CAS: 75-09-2

RTECS: PA8050000

OSHA PEL 500 PPM, C

ACGIH TLV: 50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGEST: GI DISTRESS. INHAL: OVEREXP
MAY CAUSE NOSE & THROAT IRRIT. MAY CAUSE CNS EFTS SUCH AS DIZZ,
HDCH, NAUS, STAG GAIT, CONFUSION & UNCON. RPTS HAVE ASSOC
RPTD/PRLNGD OVEREXP TO SOLV W/PERM BRAIN & NERV SYS DMG. EYE
WATERING, HDCH, NAUS, DIZZ & LOSS OF COORDINATION ARE SIGNS THAT
SOLV LEVS ARE TOO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: ANTICIPATED TO BE A
CARCINOGEN (NTP), 2B (IARC).COBALT (AS COBALT OCTOATE) GROUP 2B
(IARC)
Effects of Overexposure:HLTH HAZ:HIGH. EYE:MAY CAUSE IRRIT/BURNING.
SKIN: RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT W/DISCOMFORT &
DERM.OVEREXP MAY RSLT IN LIVER & KIDNEY DMG. FOR MORE INFO
CONCERNING HLTH HAZ OF INDIV ING, CONT NEHC . CHLOROCARBON MATLS
HAVE PRDCD SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: CALL PHYSICIAN IMMED & HAVE NAMES OF INGREDIENTS
AVAIL. DO NOT INDUCE VOMIT. INHAL: REMOVE TO FRESH AIR. IF NOT
BREATHING, GIVE ARTF RESP, PREFERABLY MOUTH TO MOUTH. IF BREATHING
DIFFICULTY PE RSISTS, OR OCCURS LATER, CONSULT PHYS. EYE:
IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES;
CALL PHYSICIAN. SKIN: WASH WITH SOAP AND WATER. IF IRRITATION
OCCURS, CONTACT PHYSICIAN.

Fire Fighting

Flash Point Method:COC
Flash Point:<20F,<-7C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP . H*2O MAY BE INEFT. H*2O FROM FOG NOZ MAY BE USED
TO COOL CLSD CNTNRS TO PVNT PRESS BUILDUP.
Unusual Fire/Explosion Hazard:CONTENTS UNDER PRESS. KEEP AT ROOM TEMP
AS EXPOS TO SUNLIGHT/OTHER HEAT MAY CAUSE CANS TO BURST, PROPELLING
CONTENTS ACROSS AREA. THERM DECOMP PRODS (SUPP DATA)

Accidental Release

Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT AND BREATHING OF VAPOR. CONFINE AND REMOVE
WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS & FLAME. DO NOT STORE ABOVE 120F. DO NOT EXPOSE
TO DIRECT SUNLIGHT TO AVOID BURSTING.
Other Precautions:WASH THORO AFTER HNDLG/BEFORE EATING/SMOKING. DO NOT
SAND, FLAME CUT, BRAZE/WELD DRY COATING W/OUT NIOSH/MSHA APPRVD
RESP/APPROP VENT. DO NOT PUNCTURE. DO NOT SPRAY NEAR FIRE/OPEN
FLAME. NO SMOKING IN AREA OF USE. DO NOT USE IN GEN (SUPDAT)

Exposure Controls

Respiratory Protection:WEAR A NIOSH/MSHA APPROVED PROPERLY FITTED
RESPIRATOR DURING AND AFTER APPLICATION UNLESS AIR MONITORING
DEMONSTRATES VAPOR/MIST LEVELS ARE BELOW APPLICABLE LIMITS.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:COVERALLS. PROTECTIVE CREAMS MAY BE USED FOR
EASE OF CLEAN-UP, NOT FOR PROTECTION.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O: APPRECIABLE, DEPENDING ON COLOR.EXPLO HAZ:MAY INCL HCL &
PHOSGENE .EFTS OF OVEREXP: SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-
SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO
CHLOROCARBONS . OTHER PREC:VICINITY OF ARC WELDING,(ING 15)

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:INGRED 14
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:0.745
Evaporation Rate & Reference:FASTER THAN ETHER
Solubility in Water:MODERATE-(SUPP DATA)
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:92

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:DO NOT STORE ABOVE 120F.
Hazardous Decomposition Products:CO, CO*2, SMOKE, OXIDES OF HEAVY
METALS REPORTED IN INGREDIENTS SECTION. HCL, PHOSGENE .

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.